Violent package errors
Vailant package errors (vailant water heater error) If you are also
using Vailant packages in your home, stay with us until the end of this
article, we have prepared a complete list of Vailant package error codes
for you dear ones. If you have a problem with your Violant package, use
this list to solve your problem.
If you need advice and guidance,
just send us the advice word through the service request form, so that
in less than an hour the experts of Tehran online service will contact
you for advice.
https://medium.com/@arezooahmadi7470/violent-package-errors-80ed6f2e8c80
Repairing the Vaillant package:
Leave the repair of your Vaylant package with confidence to Tehran Technical Engineering Group, because this group, having more than 100 active and experienced technicians in the field of Vaylant package repair, is ready to serve our dear customers 24 hours a day.
Violent package error code:
Vaylant
company is one of the reliable brands, which has also performed well in
the field of heating systems production. This company has implemented
an intelligent troubleshooting system in its packages to help in
troubleshooting its packages.
Error codes are displayed in different
ways on different devices. In old devices, this was done by turning on
the backlight or beeping. But in new generation heating systems that are
often equipped with displays, error codes appear in English letters on
the screen. One of the advantages of these codes over other methods is
the possibility of transmitting more information about the error related
to the type of problem or scope. its occurrence.
List of errors of Violent package:
Error Description of possible causes
F.00
Malfunction in the temperature sensor of the NTC socket is not
connected or is loose. The board connector is not connected correctly.
Cable problem or NTC failure
F.01
Malfunction in the heating return circuit temperature sensor, the NTC
socket is not connected or is loose. The board connector is not
connected correctly.
Cable problem or failure
F.02 Malfunction in
the output sensor of the consumer circuit, NTC failure, NTC cable
failure, cable failure on the side of the electronic parts of the
storage source
F.03 Malfunction of the storage source temperature
sensor NTC failure NTC cable failure Cable failure on the side of the
electronic parts of the storage source
F.10 NTC short circuit heating circuit failure NTC cable failure NTC short circuit in cable or socket
F.11 NTC short circuit Heating return circuit NTC failure NTC cable failure Short circuit in cable or socket
F.12 NTC short circuit, output of consumer circuit, NTC failure, NTC cable failure, short circuit in the cable or socket
F.13 Power supply temperature sensor short circuit NTC failure NTC cable failure Short circuit in cable or socket
F.20
Safety disconnection: product safety lock Improper ground connection
between cable and product, NTC faulty return or return (loose socket)
power leakage from ignition electrode or electrode cable
F.22 Safety
shutdown: low pressure, lack of water or insufficient water / defective
water pressure sensor, loose, not connected, failure of pump cable or
water pressure switch
F.23 Safety shutdown: difference in the
excessive temperature of the pump gear, insufficient pump output, the
presence of air in the circuit, wrong connection of forward or reverse
NTC
F.24 Safety shutdown: too fast temperature rise of the pump gear,
insufficient pump output, presence of air in the circuit, low pressure
in the circuit, difficulty in installing the one-way valve
F.26
error: problem in the valve, the cable of the valve is not connected,
the socket of the probe cable is not connected or is loose, valve
failure, board failure
F.27 Safety cut off: problem in moisture flame
detection in the board, failure of the ion electrode/board, leakage in
the gas valve
F.28 Ignition problem: failed ignition, gas meter
problem, air in the gas, low inlet gas pressure, improper gas limiter,
gas valve failure, cable or socket failure or loose
F.29 Faults in
operation: failed re-ignition, cut off gas inlet, fault in gas flow,
fault in earth cable, ignition problem in electrode
F.33 error: air
pressure switch, problem in the fan cable or board socket, fan gearpage,
problems in Hall sensor, problems in the board
F.45 Error: Hot water inlet sensor Hot water sensor failure
F.46 Short circuit, hot water inlet sensor
F.47 Malfunction in the water outlet sensor
F.48 Short circuit in water outlet sensor
F.49 eBUS error Short circuit in eBUS High input voltage to eBUS or wrong polarity
F.61 Error: Error in gas valve Short circuit in earth/gas valve cable
F.62 Error: Delay in closing the gas valve, failure of the gas valve, fault in the flame detection signal
F.63 Error: EEPROM board failure
F.64 Electronic/NTC board error NTC short circuit heating forward/return, board failure
F.65 Error: Electronic board temperature High board temperature due to external faults / board failure
F.67 Board/Flame Error Improper flame detection signal, board failure
F.68 error: unstable flame signal, presence of air in the gas, low gas pressure, insufficient air, ion electrode failure
F.70
Invalidity of the special device number of the board and display have
been changed at the same time and the device number has not been reset,
wrong code resistance
F.71 NTC error of the heating circuit of the positioning/improper connection of the sensor, failure of the sensor
F.72
NTC error of the heating flow/return circuit, excessive difference
between the flow and return temperature, failure of the flow/return
sensor
F.73 Short circuit in water pressure sensor, fault/short circuit of sensor cable, fault in sensor earth cable, sensor failure
F.74 Error: water pressure sensor fault/short circuit of sensor cable, fault in sensor earth cable, sensor failure
F.75
Error: no pressure change after the pump is activated, the water
pressure sensor and/or the pump is defective, the presence of air in the
heating circuit, the insufficient amount of water in the heating
circuit, check the flow control valve, put an external expansion source
in the return path .
F.77 error: chimney one-way valve / condensing pump not receiving response, chimney one-way valve failure
F.80 actoSTOR internal sensor error NTC failure, NTC cable failure, socket failure, sensor/cable short circuit, sensor failure
F.81
Error: The charging pump of the source reserve is not fully filled at
the right time: check the sensors of the source, the presence of air in
the source, the presence of air in the source pump, failure of the
three-way valve, fouling of the secondary coil, failure of the pump
F.83
Error: temperature change of the sensor of the heating flow / return
circuit when the burner is turned on, the temperature change registered
in the sensors of the flow / return circuit is not suitable:
insufficient water in the circuit, improper placement / installation of
the flow / return sensor
F.84 Error: Improper temperature difference
between the sensor and the positioning heating return circuit/improper
connection of the sensor, sensor failure
F.85 Error: Incorrect installation of heating return circuit sensors The return sensor is installed on a pipe
F.86
Underfloor heating contact open (burner input off) Burner breaker
activation (e.g. limit thermostat or underfloor heating thermostat)
F.90
Problems related to the source module, check the cable connecting the
product to the source module (PEBus, if the product should be without
the module
For actoSTOR to work, set parameter D.92 to zero
F.91 Error in storage source sensor module
Fixing the errors of the Violant package at home:
If
an error occurs in your Violant package, first reset the package or
disconnect it from the power supply. Wait for 5 to 10 minutes. Reconnect
the package to the power supply. If you see an error, you should
contact the Vaillant package expert.
Click here to read the article Iran Radiator Package Error 40 70.
Preventing errors in the Vaillant package:
In
order to prevent errors in your Vaillant package, it is enough to
service your package every 6 months. Package service must be done by an
experienced service technician every 6 months.
Often the problems
created in wall packages are due to the accumulation of rosobate inside
the package, which can be solved by acid washing and descaling of the
package.
Comments